Construction Details
Utility standard detail drawings can be downloaded as AutoCAD® DWG files or Adobe® PDF files. Please contact the Engineering Department at (915) 594-5526 for questions, comments and ordering information. These drawings are provided for informational purposes only. They are made available for use by qualified individuals. The user accepts full liability for their use.
130 |
Cover Sheet for 24" X 36" Size Sheet |
||
131 |
Utility Symbology - 1 |
||
132 |
Utility Symbology - 2 |
||
133 |
Utility Symbology - 3 |
||
140 |
Location for Utility Lines |
||
160 |
Separation Distance Potable Water, Sanitary Sewer and Reclaimed Water |
||
161 |
Separation Distance Sanitary Sewer and Potable Water (Special Conditions) |
||
162 |
Separation Distance Potable Water and Reclaimed Water (Special Conditions) |
||
163 |
Separation Distance Sanitary Sewer and Reclaimed Water (Special Conditions) |
||
170 |
Trench Cross Section Terminology |
||
171 |
Embedment Class "A" for Pressure Pipe and Gravity Pipe - Dry Conditions |
||
172 |
Embedment Class "B" for Pressure Pipe - Wet Conditions |
||
173 |
Embedment Class "C" for Gravity Pipe - Wet Conditions |
||
179 |
Pavement Replacement |
||
180 |
Carrier Pipe Installation with Casing Insulators |
||
181 |
Carrier Pipe Installation in Annular Filled Casing Pipe |
||
182 |
Concrete Cap (Paved Condition) |
||
183 |
Concrete Cap (Unpaved Condition) |
||
184-1 |
Concrete Collar Installation in Paved Areas |
||
184-2 |
Concrete Apron Installation in Non-Paved Areas |
||
185 |
Manhole Ring and Cover Installation |
||
186 |
Anchor Strap |
250 |
Cover for Water Mains |
||
260 |
Gate Valve Installation |
||
261-1 |
Butterfly Valve in Manhole Installation for 24" and Larger Water Lines |
||
261-2 |
Butterfly Valve in Manhole Installation for 16" and 20" Water Lines |
||
261-3 |
Extension Stem Guide |
||
261-4 |
Gate Valve Vertical Installation Type "A" for 16" & Larger Water Line |
||
261-5 |
Gate Valve Horizontal Installation Type "A" for 16" & Larger Water Line |
||
261-6 |
Gate Valve Vertical Installation Type "B" for 16" & Larger Water Line |
||
261-7 |
Gate Valve Horizontal Installation Type "B" for 16" & Larger Water Line |
||
262 |
Blow-Off Valve Assembly |
||
263-1 |
Combination Air Release Valve for Lines 16" and Smaller - Behind Curb Installation |
||
263-2 |
Combination Air Release Valve for Lines 16" and Smaller - Beneath Paving Installation |
||
263-3 |
Combination Air Release Valve for Lines 20" and Larger - Behind Curb Installation |
||
263-4 |
Combination Air Release Valve for Lines 20" and Larger - Beneath Paving Installation |
||
263-5 |
Break-A-Way Coupling |
||
263 |
Air Release Piping |
||
264-1 |
Pressure Reducing 6" Valve (By-Passed) - Behind Curb Installation |
||
264-2 |
Pressure Reducing 6" Valve (In-Line) - Behind Curb Installation |
||
264-3 |
Pressure Reducing 6" Valve (By-Passed) - Beneath Paving Installation |
||
264-4 |
Pressure Reducing 6" Valve (In-Line) - Beneath Paving Installation |
||
264-5 |
Pressure Test Outlet |
||
265-1 |
Pressure Relief 1" and 2" Valve (Discharge to Atmosphere) - Behind Curb Installation |
||
265-2 |
Pressure Relief 1" and 2" Valve (Back Discharge to Low Side) - Behind Curb Installation |
||
265-3 |
Pressure Relief 1" and 2" Valve (Discharge to Atmosphere) - Beneath Paving Installation |
||
265-4 |
Pressure Relief 1" and 2" Valve (Back Discharge to Low Side) - Beneath Paving Installation |
||
265-5 |
Pressure Relief 3" and Larger Valve (Discharge to Atmosphere) - Behind Curb Installation |
||
265-6 |
Pressure Relief 3" and Larger Valve (Back Discharge to Low Side) - Behind Curb Installation |
||
265-7 |
Pressure Relief 3" and Larger Valve (Discharge to Atmosphere) - Beneath Paving Installation |
||
265-8 |
Pressure Relief 3" and Larger Valve (Back Discharge to Low Side) - Beneath Paving Installation |
||
266 |
Tapping Sleeve and Valve Installation |
||
268 |
Bonnet Box |
||
269-2 |
Bonnet Box Cover (Flip Resistant) |
||
270 |
Concrete Thrust Blocking |
||
271 |
Valve Anchor |
||
272 |
Side Outlet Connection |
||
273 |
Top Outlet Connection |
||
280-1 |
Fire Hydrant Installation |
||
280-2 |
Fire Hydrant Installation (12" Main or Larger) |
||
280-3 |
Fire Hydrant Installation (Inside Parking Lot) |
||
281 |
Fire Hydrant Cap |
||
282 |
Fire Hydrant Locations |
||
283 |
Fire Hydrant Steamer Nozzle |
||
290-1 |
Service Line ¾" and 1" Installation by EPWater |
||
290-2 |
Service Line 1½" and 2" Installation by EPWater |
||
290-3 |
Service Line 3" and Larger Installation by EPWater |
||
290-4 |
Service Line ¾" and 1" Installation by Contractor |
||
290-5 |
Service Line 1½" and 2" Installation by Contractor |
||
290-6 |
Service Line 3" and Larger Installation by Contractor |
||
290-7 |
Service Line ¾" and 1" Installation for Reconnection by Contractor (Example 1) |
||
290-8 |
Service Line ¾" and 1" Installation for Reconnection by Contractor (Example 2) |
||
290-9 |
Fire Line Service Installation |
||
290-10 |
Fire Hydrant Construction Meter |
||
290-11 |
Yard Meter Line 1½" and 2" Installation by EPWater |
||
290-12 |
Yard Meter Line 1½" and 2" Installation by Contractor |
||
291 |
Meter Box Type “A” for ¾" Service Installation |
||
292 |
Meter Box Type “B” for 1" Service Installation |
||
293 |
Meter Box Type “C” for 1½" Service Installation |
||
294 |
Meter Box Type “D” for 2" Service Installation |
||
295-1 |
Meter Box Type “E” for 3" and Larger Service Installation |
||
295-2 |
Meter Box Type "F" for 3" and Larger Service Installation (H20 Loading) |
||
300 |
Meter Box Ring for Type "A" & "B" Meter Boxes |
||
301 |
Meter Box Cover for Type "A" & "B" Meter Boxes |
||
302 |
Frame and Cover for Type "C" & "D" Meter Boxes |
370-1 |
Manhole Type “A” |
||
370-2 |
Manhole Type “A1" |
||
370-3 |
Manhole Type “A2" |
||
371-1 |
Manhole Type “B” |
||
371-2 |
Manhole Type “B1" |
||
372 |
Manhole Type “C" |
||
375-1 |
Drop Connection - External Manhole Installation |
||
375-2 |
Drop Connection - Internal Manhole Installation |
||
376 |
Pipe Connection to Manhole |
||
377 |
Sewer Manhole Ring |
||
378 |
Sewer Manhole Cover |
||
379-1 |
Manhole Eccentric/Concentric Concrete Lid for Type "B" & "B1" Manholes |
||
379-2 |
Manhole Concentric Concrete Lid for Type "C" Manhole |
||
390 |
Sewer Service Riser Connection |
||
391 |
Sewer Service Riser and Service Line Connection |
||
392 |
Sewer Service Riser and Service Line Connection Within Public R.O.W. |
||
393 |
Bonnet Box for Sewer Lateral Cleanout |
||
394 |
Bonnet Box Cover for Sewer Lateral Cleanout |
||
395 |
End of Sewer Line Cleanout |
||
396 |
Bonnet Box for Cleanout |
||
397 |
Bonnet Box Cover and Extension for Cleanout |
500-1 |
Chain-Link Fence - End Post and Corner Post |
||
500-2 |
Chain-Link Fence - Line Post and Spacing |
||
500-3 |
Chain-Link Fence - Double Swing Gate |
||
500-4 |
Chain-Link Fence - Pedestrian Gate |
||
511 |
Sign Pole |
||
512 |
Site Sign - No Trespassing |
||
513-1 |
Site Sign - Reclaimed Water System Warning |
||
513-2 |
Site Sign - Reclaimed Water Irrigation System Warning |
||
514 |
Test Station Marker Plate |
||
515 |
Marker Post |
916 |
Stormwater Manhole Ring |
||
917 |
Stormwater Manhole Cover |
||
920-1 |
Stormwater Manhole Type "S-A" |
||
920-2 |
Stormwater Manhole Type "S-A1" |
||
925 |
Concrete Pipe Collar |
||
926-1 |
Pipe Connection to Stormwater Manhole Watertight Seal |
||
926-2 |
Pipe Connection to Stormwater Manhole Concrete Collar |
||
990-1 |
Chain Link Fence (Stormwater) End Post and Corner |
||
990-2 |
Chain Link Fence (Stormwater) Line Post and Spacing |
||
990-3 |
Chain Link Fence (Stormwater) Double Swing Gate |
||
990-4 |
Chain Link Fence (Stormwater) Pedestrian Gate |